Fire Extinguishing Equipment
Power Supply for Fire Extinguishing Equipment
In any case of disaster and emergency, we provide stable power for all technical consultations.
Features
- Highly reliable and long-life design
- Adopts 4 charging methods suitable for various storage batteries
- Correspondence for small lots and single items
Functions
- Overcurrent protection
- Overcurrent prevention
- Overdischarge prevention
- Floating charge/Equal charging
Automatic switching function(stationary lead acid battery)
Usage
- Control panel
- Operation equipment
- Automatic disaster notification equipment
- Gas leak/electrical leakage fire alarm system
- Broadcasting equipment
- Emergency bell
- Emergency call equipment
- Automatic call equipments
- Communication equipment
Option
- Fault-specific display function (blown fuse, etc.)
- External signal output function
- Dropper function
Integrated Package Type Automatic Fire Extinguishing Equipment
Approved by the Japan Fire Equipment Safety Center
Fire-Extinguishing Material Types
- Halide
- New gas
- Carbone dioxide
- Foam
- Powder
Function
- Equipped with noise suppression function (prevents accidental release of extinguishing agent)
- Digital display of release delay time
Specifications for controling part
Format symbol
Material
Coating color
Dimensions
Structure
Input Power
Storage battery equipment
Standard
Storage battery
Delay timer
Panel part
Common display
Operation
WKPF-A
Steel plate SPCC, thickness 1.6mm
5y7/1 semi-gloss (ivory)
W:700 D:400 H:2100 (for 2)
W:500 D:400 H:2100 (for 1)
AC100V/200V 50/60Hz
Storage battery equipment certification committee certified product
Small sealed lead acid battery 7.2Ah (standard), 15Ah
Variable up to 99 seconds
Power supply, charging, switch caution, circuit abnormality
Shut-off valve open (CO2 only), Shut-off valve closed (CO2 only), Countdown display (7SEG)
Recovery, automatic/manual key switch, battery test, buzzer stop
Specifications for operation box
For various transportation and interlocking stop connection
Direction light
Electromagnetic opener
Voice alarm device
Specification
Standard
Format symbol
Material
Coating color
Dimensions
Outer box
Equipment stop, sensor, automatic/manual, door open, fire, release during startup
Shutter closed, abnormal, shutoff valve open (CO2 only), shutoff valve closed (CO2 only)
Flashing type
Automatic recovery after activation
Certified by the Japan Fire Equipment Safety Center
Audio output: 20W
WKCB1-A
Steel plate SPCC, thickness 1.2mm (exposed type, embedded type)
Steel plate SPCC, thickness 1.2t (outdoor type)
7.5R4.5/14 Full gloss (red)
W:160 D:60 H:220
W:280 D:120 H:295
Display
Operation
Power, start, shutoff valve close (CO2 only), automatic, manual, countdown display (7SEG)
Door opening, start, emergency stop, automatic/manual change key switch
Control panel / Operation box
Approved by the Japan Fire Equipment Safety Center
- Control panel (6 circuits)
- Control panel (1 circuit)
- Compatible products manufactured by Ansur Nissho and Hayashi Seisakusho
- Operation box (exposed type/ with drip-proof box)
- Operation box (embedded type)
Specifications for controling part
Format symbol
Material
Coating color
Dimensions
Structure
Input Power
Standard
Storage battery
Storage battery equipment
Control circuit voltage
Control specifications
Delay timer
WKCP1-A
Steel plate SPCC, thickness 1.6mm
2.5y8.5/2 semi-gloss (beige)
W:500 D:200 H:600 (for 1~2 lines)
W:500 D:200 H:800 (for 3~5 lines)
W:550 D:200 H:1150 (for 6~10 lines)
AC100V/200V 50/60Hz
Storage battery equipment certification committee certified product
Small sealed lead acid battery 7.2Ah (standard), 15Ah, 24Ah
DC24V
Certification standard according to Japan Fire Equipment Safety Center
Variable up to 99 seconds
Common display
Compartment display
Operation
Panel part
Display inside the panel
For various transportation and interlocking stop connection
Direction light
Electromagnetic opener
Voice alarm device
Standard
Specification
Power supply, charging, switch caution, voice level, phone, start-up
Short circuit, earth fault, disconnection, shutoff valve open, shutoff valve closed
LED digital display, main automatic, main manual
Sensor A, sensor B, door open, fire, release, automatic, manual.
Recovery, automatic/manual key switch, battery test, buzzer stop, equipment stop cutoff, call.
Short circuit, earth fault, disconnection.
Equipment stop, sensor, automatic/manual, door open, fire, release, startup.
Shutoff valve open, shutoff valve closed.
Flashing type
Automatically recovers in about 5 seconds after activation.
Certified by the Japan Fire Equipment Safety Center, format symbol WKV0-20, certification number AA-033
Audio output: 20W
Specifications for operation box
Format symbol
Material
Coating color
Dimensions
Outer box
Control circuit voltage
Control specifications
Display
Operation
WKCB1-A
Steel plate SPCC, thickness 1.2mm
7.5R4.5/14 Full gloss (red)
W:160 D:60 H:220 (exposed type, embedded type)
W:280 D:120 H:295 (outdoor type)
DC24V
Certification standard according to Japan Fire Equipment Safety Center
Power, start, shutoff valve close (CO2 only), automatic, manual, countdown display (7SEG)
Door opening, start, emergency stop, automatic/manual change key switch, with phone jack.